----- Relay Station CBS-8 -------- --- Page No. 25
Relay output type.
The required status of the relays when not operating must be specified. There
are two possible values:
normally open normally closed
5.1.2.3.- Reclosures
The options described below only appear if this option has been activated via
communication with the “EasyComm CBS-8” software
Active in all chanells Active in chanell 1
NOTE: It is recommended to activate the self-reclosing function if the device
controls an automatic switch for handling self-reclosing. Then it is not
necessary to reset the channel tripped in the CBS-8.