PS/PSS OPC Server -1-
COMMUNICATIONS SERVER
PS/PSS OPC Server
Version 1.4
INSTRUCTION MANUAL
(M98222901-07-13A)
CIRCUTOR S.A.
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

PS/PSS OPC Server -1- COMMUNICATIONS SERVER PS/PSS OPC Server Version 1.4 INSTRUCTION MANUAL (M98222901-07-13A)  CIRCU

Page 2

PS/PSS OPC Server -10- 4. Click “Yes” again and while the program carries out the requested operations, the following window will appear: Wait pro

Page 3 - Installation welcome screen

PS/PSS OPC Server -11- ‘Load’: Gets the data from a previously saved configuration file. When you click this menu option the following window will o

Page 4

PS/PSS OPC Server -12- ‘Exit’: Ends program execution. 3.6.2.- OPC Server menu OPC Server menu ‘Register’: This option is only available when the

Page 5

PS/PSS OPC Server -13- If the action completes successfully, the application will displays the message: OPC server successfully activated If it’s

Page 6

PS/PSS OPC Server -14- If, on the other hand, there is no possible to unregister the windows service, this message will be showed: Unable to deact

Page 7 - Must get devices message

PS/PSS OPC Server -15- 3.6.3.- PowerStudio menu PowerStudio menu ‘Check connectivity’: This option allows you to verify that the details entered

Page 8

PS/PSS OPC Server -16- 3. That the connection details are correct and the server is active: Correct connection details message 3.6.4.- Tunnelling

Page 9 - Save changes ask message

PS/PSS OPC Server -17- You can also configure the Server as OPC tunnelling server, in that case is necessary to configure the port to receive the re

Page 10 - Configuration name window

PS/PSS OPC Server -18- Is posible to configure several conections with different servers of PowerStudio and configure for y configurar de forma inde

Page 11

PS/PSS OPC Server -19- 3.7.3.- Get devices If you click the button located below the server parámeters, the program will fill the list with the

Page 12 - Incorrect dongle message

PS/PSS OPC Server -2- CONTENTS 1.- INSTALLATION OF POWERSTUDIO / POWERSTUDIO SCADA OPC SERVER ... 3 2.- OPC (OLE FOR PROCESS CONTROL) ...

Page 13

PS/PSS OPC Server -20- If you attempt to set an active configuration when the OPC server is deactivated, the program will ask you if you wish to act

Page 14 - Unable to restart OPC server

PS/PSS OPC Server -21- To solve this limitation, in the PowerStudio OPC-DA Server has been implemented an OPC gateway versus Xml that allows the com

Page 15 - PowerStudio menu

PS/PSS OPC Server -22- You can restore the application by clicking the ‘Open’ option or simply by double-clicking on the icon. 3.9.1.- Server state

Page 16 - Tunnelling cliente

PS/PSS OPC Server -3- 1.- Installation of PowerStudio / PowerStudio Scada OPC server The minimum system requirements needed for the OPC server to wo

Page 17 - Help menu

PS/PSS OPC Server -4- 2.- OPC (OLE for Process Control) OPC is a communications standard in the world of process control and process data monitoring

Page 18

PS/PSS OPC Server -5- 3.3.- Basic concepts In order to better understand this manual and the operation of the PowerStudio / PowerStudio Scada OPC se

Page 19

PS/PSS OPC Server -6- o Continual requests: Requests to PowerStudio are made continually, independently of whether there are incoming OPC requests

Page 20

PS/PSS OPC Server -7- Active devices list contains PowerStudio devices that will be accessible through OPC. The first time we run the application th

Page 21 - Taskbar menu

PS/PSS OPC Server -8- If the entered connection details are incorrect, there is no internet connection, or the specified PowerStudio server is inact

Page 22 - 4.- Technical service

PS/PSS OPC Server -9- way to do this is to directly click on the “Exit” button and the application will take care of carrying out these tasks autom