Vue de la page 261
PowerStudio PowerStudio
262 User Manual
Displays general information about the device.
Value of the kWh which will be charged for the recharging. Allows you to enter a different price
for each plug.
Euros of credit: Credit in Euros that the X2 device will subtract from the card's credit on
starting recharging. On completing recharging, the X3 device will be responsible for returning
the credit not consumed. This parameter is common to both plugs.
Charge time limit for each plug (min): Maximum charge time. This parameter is common to
both plugs.
Reset time limit for the cycle by forgetting open cover(s): Whole value in seconds.
Maximum current value supported by each terminal.
Operating mode 1:
Bit 0: Paid or free service.
o 0 = Paid 1 = Free
Bit 1: Charge time limit.
o 0 = Without 1 = With
Bit 2: Credits.
o 0 = Credit units 1 = All credit available
Bit 3: "Anti-theft" meter system, Plug 1 and 2.
o 0 = YES 1 = NO
Bit 4: Continue cycle after a "Power Fail".
o 0 = NO 1 = YES
Bit 5: Plug 1. Functionality.