Vue de la page 31
CDP
32 Instruction Manual
Disconnection condition:

 
< .  
(

= 0%) 0% ≤ 50%
this condition is met
relay 2 stays connected
At this point, the CDP-G will check whether it can connect the third load. To do
so, it must verify whether the connection condition is met:
Condition 1:

 
100 .  
(


100 = 80%) 80% ≤ 90% this condition is met
Condition 2:
-If Injection Margin = 0% It checks whether:
Pgrid < 2 x (0.03) x Pconsumed
-If Injection Margin ≠ 0% It checks whether:
Pgrid < 2 x Injection Margin x Pconsumed
0 < 2 x 0.03 x 8000 this condition is met
If the 2 conditions are met, the relay closes and connects load number 3.