After T2, the output drops to 50% of the power, during a period of time T3. After the time period
T3 has elapsed, the output returns to 100% until the end of time period T4.
The CirLAMP system works with two types of work intervals:
Memory work interval, with this system up to four different work intervals can be con-
gured through the CirLAMP Manager. The CirLAMP Node saves the work intervals in
the memory and operates autonomously so there is no need to send PLC commands for
each of the intervals.
The different light points are activated simultaneously since a general synchronisation is
completed on each start-up (every day).
Work time interval, a PLC command can be sent at any time to modify the % of pow-
er sent to the load, as well as the time period for this new power, in the work period which
is being executed at that moment.
When the period is changed the CirLAMP Node continues to work with the memory
intervals.
See “4.6.3.1.2. Instantaneous values” to program the work intervals.
6�3�2� ALARMS
The CirLAMP Nodes can detect a burnt out lamp, an open capacitor and a blinking light, and
generate an alarm.
See 5.3.2. ALARMS”.
6�3�3� MEASUREMENT PARAMETERS
See “5.3.3. MEASUREMENT PARAMETERS”.