Circutor computer PLUS-TF Series Manuel d'utilisateur Page 43

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 69
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 42
43
Select the Compensation (Fig.58) option and press OK The screen on Fig.59 will be displayed.
Press Edit to adjust the desired parameter values.
Fig. 58.- Tact, Trec Menu
Fig. 59.- Edit Tact, Trec Menu
The options available are:
In Comp you can select three options TRIPH or PH-PH which means three-phase or Phase-
Phase compensation, respectively.
In Man you can select the following options: FCP or LINIAL. These options are related to the
steps sequence in FIFO (FCP) or LIFO (LINIAL) mode. The FIFO mode means first in - first out
(disconnected) and the LINIAL mode means that the last one in is the first one disconnected.
In Contrl you can select the following options: SEC or TOTAL. SEC means that there is a
sequential step input (one by one, respecting Tact). TOTAL means that all steps required to reach
the desired cos will be connected at once.
In Mode… you can choose between RUN or STOP, to start or stop Computer plus.
To edit a field, follow the procedure described in section 5.4.
7.3.10 Adjusting the Date and Time
Open the setup menu by following the procedure described in section 7.3.2.
Select the Date / Time (Fig.60) option and press OK . The screen on Fig.61 will be displayed.
Press Edit to adjust the desired day/month/year and hour:minute:second values.
To edit a field, follow the procedure described in section 5.4.