Circutor DHB Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Circutor DHB Series. CIRCUTOR DHB Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - INSTRUCTION MANUAL

DHB-302DHB-324INSTRUCTION MANUALSingle-phase Vac analyzer(M044B01-03-14A)

Page 2

10(Model DHB-324)DHB-302 / DHB-324Fig. 5. Electrical connections of the DHB-3xx meter for indirect measurements

Page 3 - Contents

115. SERVICE5.1. Display DescriptionFig. 6. Description of the meter frontal plate5.2. Messages after switching the supply onAfter switching the switc

Page 4

125.3. Functions of buttons - Acceptation button:⇒ entry in programming mode (hold down ca 3 secondes) (przytrzymanie przez około 3 sekund),⇒ mo

Page 5

13⇒ resignation of the parameter change,⇒ absolute exit from the programming mode.The pressure of the button combination and holding down them

Page 6 - 2. METER SET

14Fig. 7. Algorithm of the DHB-3xx meter service

Page 7

15of averaged values are performed, respectively: the averaged power every 15 seconds, the averaged voltage every 5 seconds and the ave-raged frequenc

Page 8 - 4. INSTALLATION

16Fig. 8. Transition matrix in the programming mode* Do not occur in the execution without additional output plate.

Page 9 - 4.1. Connection Diagrams

17Value Change Way of the Chosen ParameterChange of Integral ValuesIn order to increase the value of the chosen parameter, one must press the buton.

Page 10 - DHB-302 / DHB-324

18Table 1Para-meter symbolDescription Range of changestYPChoice of the displayed quantityU – RMS voltageI – RMS currentP – active powerq – reactive po

Page 11 - 5. SERVICE

19dpMinimal position of the decimal point when displaying the measured value. 0.0000 – 0 00.000 – 1 000.00

Page 13

20P_A1P_A2P_A3P_A4Kind of input value type, which the alarm has to react on.U – RMS voltageI – RMS currentP – active powerq – reactive powerS – appare

Page 14

21LEd_1LEd_2LEd_3LEd_4Supporting of alarm signaling. In the situation when the support function is switched on after the alarm state retreat, the sign

Page 15 - 5.4. Programming

22bAUdBaud rate of the RS-485 interface transmission. 4800 – 4800 bit/s 9600 – 9600 bit/s19200 – 19200 bit/s38400 – 38400 bit/sProtKind of t

Page 16 - * Do not occur in the

23C_EnqReset of reactive watt-hour metersThe choice YES causes the reset of reactive watt-hour meters.C_PAvSynchronization of 15 minutes’ mean active

Page 17

24Caution!l In case of alarms of n-on, n-oFF, on, oFF types the write of PrL>PrH will cause the alarm switching off.l In case of a measuring r

Page 18

25ovrHI 2 -19999MP_A 1 3 PPrL_1 3 920PrH_1 3 1150tYP_1, 3 n-onP_A 2 4 IPrL_2 4 4.000PrH_2 4 5.000tYP_2, 4 n-onP_A3 5 UPrL_3 5 200.00PrH_3 5 250.00tYP

Page 19

26DHB-324DHB-324DHB-3246. INTERFACE RS-485DHB-3xx programmable digital meters have serial links in RS-485 standards for the communication in computer

Page 20

27tection terminal (it is not necessary for a correct interface work).To obtain the connection with a computer of IBM PC class, a RS-485 card or a RS-

Page 21

28Table 4Range of addressesValue type Description4000-4100 integer (16 bitów) Value placed in a 16-bit register. 7000-7199 float (32 bity)Value place

Page 22

29Table 5Values placed In 16-bit registersWrite (w)/Readout (r)Input type4000tYPw/r 0...16Range DescriptionSymbolSynchronization of input4001SYnw/r 0.

Page 23

3Contents 1. APPLICATION and METER DESIGN ...5 2. METER SET ...

Page 24

30Voltage input range4002rAn Uw/r 0...1Value 0 Range 100 V 1 Range 400 VCurrent input range4003rAn Iw/r 0...1Value 0 Range 1 A 1 Range 5 AVolt

Page 25

31Display colour when the displayed value is higher than in the register 7600 and less than in register 7601.4011CoLbEw/r 0...2Value 0 red 1 green

Page 26 - 6. INTERFACE RS-485

32Type of alarm 1 (description – fig. 6)4014tYP_1w/r 0...5Value 0 n- on 1 n- oFF 2 on 3 oFF 4 H- on 5 H- oFFSupport of alarm 1 signaling4016LEd_

Page 27 - Implementation

33Type of alarm 2 (description – fig. 6)4018tYP_2w/r 0...5Value 0 n- on 1 n- oFF 2 on 3 oFF 4 H- on 5 H- oFFSupport of alarm 2 signaling4020LEd_

Page 28

34Type of alarmu 3 (description – fig. 6)4022tYP_3w/r 0...5Value 0 n- on 1 n- oFF 2 on 3 oFF 4 H- on 5 H- oFFSupport of alarm 3 signaling4024LEd

Page 29

35Type of alarm 4 (description – fig. 6)4026tYP_4w/r 0...5Value 0 n- on 1 n- oFF 2 on 3 oFF 4 H- on 5 H- oFFSupport of alarm 4 signaling4028LEd_

Page 30

36Type of analog output4030tYP_Aw/r 0...2Value 0 Voltage 0...10 V 1 Current 0...20 mA 2 Current 4...20 mABaud rate4031bAUdw/r 0...3Value 0 480

Page 31

37Switch on and off the unit display4038Unitw/r 0...16 0 RMS voltage 1 RMS current 2 Active power 3 Reactive power 4 Apparent power 5 Acti

Page 32

38Synchronization of the 10 minutes’ mean voltage4042C_UAvw/r 0...1Value 0 Lack of operation 1 Beginning of the 10 minutes’ mean voltage synch

Page 33

39Status register (address 4044, R):bits X X X X X X X X X X X X X X X X 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0damage of non-volatile memoryno cal

Page 35

40Bit 11Bit 10Meaning0 0 voltage output 0...10 V0 1 current output 0...20 mA1 0 current output 4...20 mA1 1 lack of calibration of analog outputBit-9

Page 36

41Bit-15 - negative active energy difference (register 7518)Bit-14...3 - reservedBit-2 - „1” - capacitive reactive power maximumBit-1 - „1” - ca

Page 37

42Table 6The value placed In two suc-cessive 16-bit registers. These registers include the same data as 32-bit registers from the area 7600write (w)/r

Page 38

436.5. Registers only for ReadoutTable 7The value placed In two suc-cessive 16-bit registers. These registers include the same data as 32-bit registe

Page 39 - Analog output

4470247512 Q r var Reactive power70267513 S r VA Apparent power70287514 PF r Active power factor70307515 tG r Ratio of reactive/active power70327516 F

Page 40

457076 7538 tG_max r Maximal value of reactive/active power ratio7078 7539 FI_min r°Minimal value of phase shift70807540 FI_maxr°Maximal value of pha

Page 41

467. ERROR CODESAfter switching the meter to the network, messages about errors can appear. Reasons about errors are presented below.The appearance o

Page 42

47During the meter operation, messages about errors can appear. Rea-sons of errors are presented below: 1) Erovr - when the voltage and/or current is

Page 43

48 Measured value Indication range Measuring range Basic error Current 1 A 0.000...12 kA 0.005...1.200 A~ ±0.2%

Page 44

49Serial interfaces (DHB-324) RS485: address 1...247 Mode: 8N2, 8E1, 8O1,8N1 Baud rate: 4.8, 9.6, 19.2, 38.4 kbit/s Transmission protocol: Modbus

Page 45

51. APPLICATION AND METER DESIGNThe DHB-3xx meter is a programmable digital panel meter destined for the measurement of a.c. voltage, a.c. current, ac

Page 46 - 7. ERROR CODES

50- input signal 0...0.005...1.2In; 0.05...1.2Un for current, voltage 0...0.1...1.2In; 0...0.1...1.2Un; for coefficients Pfi, tji, j frequency

Page 47

519. MAINTENANCE AND TECHNICAL SERVICEIn the case of any query in relation to unit operation or malfunction, please contact the CIRCUTOR, SA Technical

Page 48 - 8. TECHNICAL DATA

5210. GUARANTEECIRCUTOR guarantees its products against any manufacturing defect for two years after the delivery of the units. • No returns will be

Page 50

54CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circu

Page 51 - 9. MAINTENANCE AND TECHNICAL

62. METER SETThe set is composed of:- DHB-3xx meter ... 1 pc- User’s manual ... 1

Page 52 - 10. GUARANTEE

73. BASIC REQUIREMENTS, OPERATIONAL SAFETYIn the safety service scope, the meter meets the requirements of the EN 61010-1 standard.Observations concer

Page 53

8Fig. 2. Meter fixing User’s Manual.4. INSTALLATIONThe meter has separable strips with screw terminals which enable the connection of external wires

Page 54 - Vial Sant Jordi, s/n

94.1. Connection Diagrams(Model DHB-324)DHB-302 / DHB-324Fig. 3. Overall dimensionsFig. 4. Electrical connections of the DHB-3xx meter for direct me