Use the keys and to browse the various parameters.
If there is an alarm associated with the variable being displayed, the following will be shown:
The module with which the alarm is associated.
The associated output in the module.
The alarm status:
not activated, pre-alarm activated, alarm activated.
The
icon flashes during the delay time in the alarm connection (ON) and
disconnection (OFF).
The menu in the lower area disappears after a few seconds.
Press the
key to display the lower area again.
The following icons also appear in the lower area:
Back, returns to the default parameters display screen, Figure 65.
Main Menu, back to the main menu, Figure 25.
If you press the key
while selecting a display parameter, you will enter the parameter
display menu.
5.1.3.1.3.1.- Demand parameters display menu.
For each demand parameter, this menu enables (Figure 75):
Figure 75: Demand parameters, display menu (display 4 parameters).
Graphic view.( 5.1.3.1.3.1.1. Graphic view.)
Tariff selection (“5.1.3.1.3.1.2. Tariff selection.”)